Light Ageing Test-UV Exposure and Vertical Burning Test of Nylon Thatch Roof For Thailand Resort Projects
Product type: nylon thatch roof
Project location: Bangkok in Thailand
Application: Gazebo thatched roof for resort hotel
Project installation time: on April, 2019 before peak seaon of tourism industry
Product size: 1000x500mm
Product request: the synthetic thatch roof is requested to be fireproof
Areas: 1000 square meters
Time for issuing the test report: 30 days
Test standard:
1) 720 hours light ageing UV exposure test: ASTM G154-16 Cycle1 & ISO 105-A02:1993/Cor.2:2005
Test Condition:
Exposure cycle:
ASTM G154-16 cycle 1
Lamp type: UVA-340
8h UV at (60±3)℃ BPT, 0.89W/(m2•nm)@340nm
4h condensation at (50±3)℃ BPT
Exposure duration: 720h
Test result: a little discolration
2) Vertical Burning:
Test Method: With reference to UL 94-2013 Rev.8-2017 Section 8 and client’s requirement
Test Condition:
Specimen: 128mm×13.2mm×0.78mm (maximum thickness)
Test Result: 6 items passed and rank class "V-0" (the best class), 1 item rank class "V-2"
Welcome your inquiry to us
Tel: +8613400623179
Whatsapp: +8613400623179
Email : jack.lim@beatlesbm.com
Group 2, Zhaishang Village, Huli District, Xiamen, China